6.3.4.3 IOT HFSI List
Chain-Link HFSI Name
950-800
BTR Unit
950-801
Fusing Unit
950-802
MSI Feed Roll/Nudger
Roll/Retard Pad
950-803
Tray1 Feed Roll/Retard
Pad
950-804
Tray2 Feed/Retard/Nudger
Roll
950-805
Deodorant Filter
950-807
Drum_Cycle_Counter
General Procedures
6.3.4.3
Life Value
Count Condition
10,000,000
Counts up when paper passes through the Fusing Unit Exit Sensor.The count value is
determined based on multiples of paper length in 216 mm.0 mm < Paper Length <=
216 mm: 1 Count Up216 mm < Paper Length <= 432 mm: 2 Counts Up
To clear the counter, enter the HFSI Counter Read / Clear Mode and select [Clear] ->
[Start] to clear it to '0'.
This can count up to the maximum of 99,999,999 and the maximum value is retained
until the counter is cleared.
17,500,000
Counts up when paper passes through the Fusing Unit Exit Sensor.
The conversion value is calculated with 1 sheet of A4 L being equivalent to a value of
100.
Count value = Paper Length [0.1 mm]/21
To clear the counter, enter the HFSI Counter Read / Clear Mode and select [Clear] ->
[Start] to clear it to '0'.
This can count up to the maximum of 99,999,999 and the maximum value is retained
until the counter is cleared.
50,000
Counts up at feeding from MSI.
To clear the counter, enter the HFSI Counter Read / Clear Mode and select [Clear] ->
[Start] to clear it to '0'.
This can count up to the maximum of 999,999 and the maximum value is retained until
the counter is cleared.
50,000
Counts up at feeding from Tray 1.
To clear the counter, enter the HFSI Counter Read / Clear Mode and select [Clear] ->
[Start] to clear it to '0'.
This can count up to the maximum of 999,999 and the maximum value is retained until
the counter is cleared.
300,000
Counts up at feeding from Tray 2.
To clear the counter, enter the HFSI Counter Read / Clear Mode and select [Clear] ->
[Start] to clear it to '0'.
This can count up to the maximum of 999,999 and the maximum value is retained until
the counter is cleared.
-
Not used
[18PPM]
Counts up at each 0.1 cycle.
343K Cycle
This can count up to the maximum of 8,000,000 and the maximum value is retained
(Ref 75K PV)
until the counter is cleared.
[20PPM]
343K Cycle
(Ref 80K PV)
Table 1 IOT HFSI List
08/2012
6-38
Description
BTR Unit ON Count (PV conversion)
No. of sheets transported through the Fusing
Unit
(A4 LEF conversion value)
No. of sheets fed to MSI Feed Roll, MSI
Nudger Roll, and MSI Retard Pad
No. of sheets fed to Tray 1 Feed Roll and Tray
1 Retard Pad.
No. of sheets fed through Tray 2 Feed Roll,
Tray 2 Retard Roll, and Tray 2 Nudger Roll
Initial Issue