6.3.8 NVM DRIVE & NOHAD
Chain-Link
NVM Name
741-001
DRV_MAIN_MOTOR_SPEED
741-002
NOHAD_PRINT_STOP_DELAY
741-003
NOHAD_STBY_MODE_INTVAL
741-004
NOHAD_STBY_MODE_COUNT_THRESHOLD
741-005
NOHAD_STBY_MODE_TEMP_THRESHOLD
741-006
NOHAD_STBY_MODE_SWITCH
741-007
NOHAD_COLD_MODE_TEMP_THRESHOLD
741-008
NOHAD_COLD_MODE_HOLD_TIME
741-027
NOHAD_CONDENSE_SWITCH
741-028
NOHAD_CONDENSE_ENTRY_TEMP_THRESHOLD 0
741-029
NOHAD_CONDENSE_HOLD_TIME
741-030
NOHAD_SMELL_FILTER_SWITCH
741-032
NOHAD_FAN_FAIL_START_TIMER
741-033
NOHAD_FAN_FAIL_SUMPLE_TIME_THRESHOLD
Initial Issue
WorkCentre 5021/5019
Table 1 NVM DRIVE & NOHAD
Setting
Setting
Range
Range
(Minimum
(Maximum
Default
Value)
Value)
Value
1040000
1562000
1301028
15
1800
15
1
20
1
1
20
3
0
800
245
0
1
1
0
300
140
0
180
0
0
1
0
300
120
0
240
90
0
1
0
0
60
6
10
300
48
08/2012
6-51
Write
Initialization
Yes/No
Yes/No
Description
Enable
Enable
main motor speed
(Unit: Ref CLK)
Enable
Enable
The time for Fan high speed rotation after printing has
completed.
(Unit: 1 s)
Enable
Enable
The temperature sampling time for Fusing Fan Tempera-
ture Control.
(Unit: 1 s)
Enable
Enable
The threshold count for determining the mode transition of
the Fusing Fan Temperature Control.
(Unit: times)
Enable
Enable
The threshold temperature for determining the mode tran-
sition of the Fusing Fan Temperature Control.
(Unit: 0.1 degrees C)
Enable
Enable
Fusing Fan Temperature Control Execution Switch
0: Do not perform
1: Perform
Enable
Enable
The threshold temperature for determining the Fan Low
Temperature Stop Operation.
(Unit: 0.1 degrees C)
Enable
Enable
The time to maintain the Fan in low speed rotation for Fan
Low Temperature Stop Operation.
(Unit: 1 s)
Enable
Enable
Condensation Mode Execution Switch
0: Do not perform
1: Perform
Enable
Enable
The threshold temperature for determining whether to
transition to the Condensation Mode.
(Unit: 0.1 degrees C)
Enable
Enable
The time where the transition to the Sleep Mode is prohib-
ited after entering the Condensation Mode.
(Unit: min)
Enable
Enable
Deodorant Filter Availability Switch
0: No Deodorant Filter
1: Deodorant Filter available
Enable
Enable
The time where Fail Detection is prohibited after the Fan
operation.
(Unit: 1 s)
Enable
Enable
Fan Fail Signal Accumulated Time
(Unit: 1 s)
General Procedures
6.3.8