6.3.12 NVM XERO
Chain-Link
NVM Name
745-015
XERO_TEMP_DATA
745-097
XERO_BTR_OUTPUT_SIDE1_BIAS
745-098
XERO_BTR_OUTPUT_SIDE2_BIAS
745-100
XERO_BTR_CORR_COEF_PLAIN_SIDE1
745-101
XERO_BTR_CORR_COEF_PLAIN_SIDE2
745-102
XERO_BTR_CORR_COEF_HEAVY_SIDE1 0
745-103
XERO_BTR_CORR_COEF_HEAVY_SIDE2 0
745-104
XERO_BTR_NET_OUTPUT_SIDE1_BIAS
745-105
XERO_BTR_NET_OUTPUT_SIDE2_BIAS
750-001
XERO_BCR_AC_IO_BIAS
750-002
XERO_BCR_DC_IO_BIAS
750-003
XERO_DEVE_IO_BIAS
750-023
XERO_DRUM_CYCLE
750-024
XERO_DRUM_PV
750-025
XERO_TOTAL_DRUM_CYCLE
750-026
XERO_TOTAL_DRUM_PV
750-051
XERO_DRUM_PRE_NEAR_CYCLE_DATA
750-052
XERO_DRUM_PRE_NEAR_PV_DATA
750-053
XERO_DRUM_PRE_NEAR_TICK_DATA
Initial Issue
WorkCentre 5021/5019
Table 1 NVM XERO
Setting
Setting
Range
Range
(Minimum
(Maximum
Default
Value)
Value)
Value
-20
60
18
0
200
80
0
200
80
0
200
100
0
200
100
200
100
200
100
0
200
80
0
200
80
0
222
121
0
100
74
0
100
86
0
8000000
0
0
200000
0
0
4294967295
0
0
4294967295
0
0
65535
0
0
65535
0
0
5000
0
08/2012
6-59
Write
Initialization
Yes/No
Yes/No
Description
Enable
Enable
Stores the temperature detection result.
(Unit: 1 degrees C)
Enable
Enable
Stores the BTR Output (Side 1)
(Unit: 0.1 MicroAmp)
Enable
Enable
Stores the BTR Output (Side 2)
(Unit: 0.1 MicroAmp)
Enable
Disable
BTR Output Correction Coefficient (for Plain Side 1)
(Unit: %)
Enable
Disable
BTR Output Correction Coefficient (for Plain Side 2)
(Unit: %)
Enable
Disable
BTR Output Correction Coefficient (for Heavyweight Side 1)
(Unit: %)
Enable
Disable
BTR Output Correction Coefficient (for Heavyweight Side 2)
(Unit: %)
Enable
Enable
Stores the BTR Final Output (for Side 1)
(Unit: 0.1 MicroAmp)
Enable
Enable
Stores the BTR Final Output (for Side 2)
(Unit: 0.1 MicroAmp)
Enable
Disable
BCR-AC I/O Check Output Value
(Unit: 3.95 MicroAmp)
Enable
Disable
BCR-DC I/O Check Output Value
(Unit: 1%)
Enable
Disable
Deve-DC I/O Check Output Value
(Unit: 1%)
Disable
Enable
Drum Cycle
(Unit: 0.1 cycle)
Disable
Enable
Drum PV
(Unit: 1 sheet)
Enable
Enable
M/C Total Cycle
(Unit: 0.1 cycle)
Enable
Enable
M/C Total PV
(Unit: 1 sheet)
Enable
Enable
Cycle Count When Pre Near Occurs
(Unit: 100 cycle)
Enable
Enable
PV When Pre Near Occurs
(Unit: 100 sheet)
Enable
Enable
Remaining Film Thickness When Pre Near Occurs
(Unit: 0.01 Micrometer)
General Procedures