Figure 2 j0lj64004
5.
When the initialization has completed successfully, [End] will flash twice -> remain ON to
indicate the completion of the [NVM] initialization.
6.
Pressing the [Clear All] button returns you to the [Chain-Link Number Entry] screen.
General Procedures
6.4.2.5, 6.4.2.6
6.4.2.6 Component Check (IOT/IIT/DADF)
Purpose
Displays the logic state of Input Component input signals and operates the Output Compo-
nents.
NOTE: For more details on the Component Check Code, refer to 6.3.1 and 6.3.2 in Chapter 6.
Procedure
<Input Component Check>
1.
Enter the CE Diag Mode.
2.
Input the Chain-Link No. and press the [Start] button.
The value is refreshed in 1/3 second.
3.
The result of Input Check is displayed as 'HI' for High Level and 'LO' for Low Level.
Example of High Level
4.
Pressing the [Stop] button causes the [End] to flash twice -> remain ON to indicate that
the Input Check has completed.
5.
Pressing the [Clear All] button returns you to the [Chain-Link Number Entry] screen.
<Output Component Check>
1.
Enter the CE Diag Mode.
2.
Input the Chain-Link No. and press the [Start] button.
When an Output Component is in operation, an animation will be displayed to indi-
cate that it is in progress.