Figure 2 j0lj64004
4.
When the clear all has completed successfully, [End] will flash twice -> remain ON to indi-
cate the completion of the [Jam Counter] reset.
5.
Pressing the [Clear All] button returns you to the [Chain-Link Number Entry] screen.
General Procedures
6.4.2.10, 6.4.2.11
6.4.2.11 DRUM Counter Reset
Purpose
To reset the Drum Counter.
NOTE: Check the completed [Drum Counter Reset] at
Procedure
1.
Enter the CE Diag Mode and input 950-807 in the Chain-Link.
2.
Pressing the [Start] button transitions to the [Check Initialization] screen. At this time, the
[CLR] and the [Start] button will be flashing.
3.
Pressing the [Start] button starts the reset of the [Drum Counter].
•
An animation will be displayed to indicate that it is in progress.
08/2012
6-100
[6.4.2.7
Maintenance Report].
Figure 1 j0lj64003
Figure 2 j0lj64004
WorkCentre 5021/5019