LSLA
Operation:
Description:
Shifts all bits of accumulator A one place to the left. Bit 0 is loaded with
zero. The C status bit is loaded from the most significant bit of A.
Condition Codes and Boolean Formulas:
S
N:
Z:
V:
C:
Addressing Modes, Machine Code, and Execution Times:
Source Form
LSLA
MOTOROLA
6-132
Logical Shift Left A
(Same as ASLA)
C
b7
– – – – – –
X
H
I
N
Z
Set if MSB of result is set; cleared otherwise.
Set if result is $00; cleared otherwise.
N ⊕ C = [N • C] + [N • C] (for N and C after the shift)
Set if (N is set and C is cleared) or (N is cleared and C is set); cleared oth-
erwise (for values of N and C after the shift).
A7
Set if the LSB of A was set before the shift; cleared otherwise.
Address Mode
INH
INSTRUCTION GLOSSARY
0
b0
V
C
Object Code
48
LSLA
Cycles
Access Detail
1
O