Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 142
clink_mute
Argument
Argument value
Channel Type
Device-Specific System
Value Type
Boolean
Read/Write Mode
Read/Write
Default
0
Event Source
Yes
Description
This parameter gets or sets the mute status of an HDX or HDX Microphone
Array attached to the indicated device. This does not actually mute any audio.
It only reflects the settings of the red mute LEDs on HDX Microphone Arrays,
or the mic mute display on an HDX. A status message is generated whenever
the mute status is changed by an HDX or HDX Microphone Array.
clink_volume
Argument
Argument value
Channel Type
Device-Specific System
Value Type
Integer
Read/Write Mode
Read/Write
System Limits
Minimum: 0, maximum: 51
Default
31
User Limits
No
Supported
Event Source
Yes
Description
This parameter gets or sets the volume status of an HDX. This does not actu-
ally adjust any gains. It only reflects the settings of the on-screen volume
control bar of the HDX. A status message is generated whenever the volume
is changed by an HDX.
Clink2 Mute Status
CLink2 Volume Status