Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12

SoundStructure VoIP Interface Settings on the Wiring Page

Setting an IP address with SoundStructure Studio
12 - 44
The wiring page has several options for configuring the SoundStructure VoIP
Interface that are active only when connected online with a SoundStructure
system that has a SoundStructure VoIP Interface.
Button Name
Edit Network Settings
Web Configuration
Local Configuration
Reset
Factory Reset
You can set the IP address and other Ethernet settings of the SoundStructure
VoIP Interface via SoundStructure Studio when connected to an online Sound-
Structure system. To set Ethernet settings use the following steps:
1. Connect to the SoundStructure system with SoundStructure Studio and
select the Wiring page
Description
Opens the VoIP Network Settings user interface control
for manually configuring the Ethernet settings for the
SoundStructure VoIP Interface.
Launches the default browser with the IP address of the
SoundStructure VoIP Interface.
Resets to default values the auto answer, entry and exit
tones, Do Not Disturb, and ringtone selection settings in
the Telephony Settings. You will be prompted to the
confirm after selecting this option.
Resets the SoundStructure VoIP Interface to its factory
default settings. This will clear all Ethernet settings,
provisioning server settings, line registrations, and all
other VoIP-specific parameters. You will be prompted to
confirm after selecting this option. Before using this
option you may want to use the Utilities > Phone
Backup and Restore options from the Web
Configuration Utility to save the VoIP-specific settings.