Description
This parameter defines the peak hold behavior of all of the peak meters in the
system. If the infinite peak hold mode is selected, the peaks can be reset using
the meter_peak_reset parameter.
meter_peak_reset
Argument
Argument value
Channel Type
Global System
Value Type
Void
Read/Write Mode
Write-Only
Event Source
No
Description
This parameter resets all of the peak meters in the system, if the peak meters
are configured to have the infinite peak hold behavior.
mic_in_gain
Argument
Argument value
Channel Type
Virtual Channel
Value Type
Floating-Point
Read/Write Mode
Read/Write
Phys Chans
Conferencing Mic/Line Input, Sound Reinforcement Mic/Line
Input
Virt Chans
Mono, Stereo
System Limits
Minimum: -20.0, Maximum: 64.0, Resolution: 0.5
Default
0.0
User Limits
No
Supported
Event Source
No
Description
This parameter sets the gain (in dB) of the mic pre-amp. A separate mic/line
control is not provided. Instead, a continuous gain range is provided, and the
firmware will map this to the appropriate mic/line switch and pre-amp gain
settings.
Command Protocol Reference Guide
Meter Peak Reset
Mic Input Pre-Amp Gain
A - 33