A - 134
am_hold_time
Argument
Argument value
Channel Type
Global Systems
Value Type
Integer
Read/Write Mode
Read/Write
Indices
1-63 : group number
Systems Limits
Minimum: 100, Maximum: 10000
Default
500
User Limits
No
Supported
Event Source
No
Description
This parameter defines how long (in ms) the microphone in the specified auto-
mixer group will be considered active after the last detected significant level
on the microphone.
am_last_mic_mode
Argument
Argument value
Channel Type
Virtual Channel
Value Type
Boolean
Read/Write Mode
Read/Write
Phys Chans
Conferencing Mic/Line Input, Sound Reinforcement Mic/Line
Input
Virt Chans
Mono, Stereo
Default
0
Event Source
No
Description
When this parameter is set to 1, the last mic mode is enabled on the
microphone.
Automixer Hold Time
Automixer Last Mic Mode