Polycom SoundStructure C16 Design Manual page 642

Hide thumbs Also See for SoundStructure C16:
Table of Contents

Advertisement

Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 126
sig_gen_sweep_time
Argument
Argument value
Channel Type
Virtual Channel
Value Type
Integer
Read/Write Mode
Read/Write
Phys Chans
Signal Generator
Virt Chans
Mono
System Limits
Minimum: 10, Maximum: 60000
Default
10000
User Limits
No
Supported
Event Source
No
Description
When the signal generator's sig_gen_type is set to sweep, this parameter sets
the duration (in milliseconds) that the sweep generator takes to sweep from its
start frequency to its stop frequency.
sig_gen_tone_freq
Argument
Argument value
Channel Type
Virtual Channel
Value Type
Floating-Point
Read/Write Mode
Read/Write
Phys Chans
Signal Generator
Virt Chans
Mono
System Limits
Minimum: 20.0, Maximum: 20000.0, Resolution: 0.1
Default
1000.0
User Limits
No
Supported
Event Source
No
Description
This parameter sets the frequency (in Hz) of the sine wave produced by the
signal generator when its sig_gen_type is set to tone.
Signal Generator Sweep Time
Signal Generator Tone Frequency

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SoundStructure C16 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents