Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 124
Description
This parameter sets the gain of the signal produced by the signal generator, in
dB. A gain of 0 dB will produce a signal that has the same RMS level as a sine
wave at -20 dBFS (the nominal signal level). This means that not all signal
types will have the same peak level, and some types may clip before a gain of
20 dB is applied.
sig_gen_sweep_start
Argument
Argument value
Channel Type
Virtual Channel
Value Type
Floating-Point
Read/Write Mode
Read/Write
Phys Chans
Signal Generator
Virt Chans
Mono
System Limits
Minimum: 20.0, Maximum: 20000.0, Resolution: 0.1
Default
20.0
User Limits
No
Supported
Event Source
No
Description
When the signal generator's sig_gen_type is set to sweep, this parameter sets
the frequency (in Hz) at which the sweep generator begins. The direction of the
frequency sweep will be up or down depending on whether this parameter is
higher or lower than the sig_gen_sweep_stop parameter.
sig_gen_sweep_step
Argument
Argument value
Channel Type
Virtual Channel
Value Type
List
Read/Write Mode
Read/Write
Phys Chans
Signal Generator
Signal Generator Sweep Start Frequency
Signal Generator Sweep Step Size
Need help?
Do you have a question about the SoundStructure C16 and is the answer not in the manual?
Questions and answers