2.4.2 CC-Link Slave Module Installation
■ Make sure that the power is turned OFF before installing/removing any modules
or connecting/disconnecting any cables. Installing/removing any boards or
connecting/disconnecting any cables with the power ON is extremely hazardous
WARNING
and may result in electric shock and/or malfunction of equipment.
■ Pay attention to the followings in order to prevent the the DeviceNet connecter
from coming off.
1. Use the connectors attached to the module.
2. Insert the connectors all the way seated.
CAUTION
3. Fix the cables at proper positions in order not to put a load on the
Appearance
Specifications
Name
Connection Method
Baud Rates (bps)
Transfer Distance
Maximum Device Number
Cable
Mode
Interface
Occupied Stations
Master Station's Handshake
Max. Input Data Size
Max. Output Data Size
RC700 / RC90 Option Fieldbus I/O Rev.12
connectors.
Run LED
CC-Link Connector
Items
Error LED
Specification
CC-Link Slave Module
Broadcast polling
156 k, 625 k, 2.5 M, 5 M, 10 M (bps)
Baud Rates
10 M (bps)
5 M (bps)
2.5 M (bps)
625 k (bps)
156 k (bps)
64 units
Dedicated cable supporting CC-Link Ver.1.10
Slave
1 CC-Link V1 port
1 to 4 station(s) (Remote device station)
384bits (48bytes)
384bits (48bytes)
2. Installation
Cable Length
100 m
160 m
400 m
900 m
1200 m
149