4. Troubleshooting (EtherNet/IP)
TCP/IP tool
By clicking in the <
displays the following options.
See also: To display the help, select [Start]-[Program]-[Direct-Link]-[applicomIO 2.3]-
[Help].
1. Resolution of IP address or name
262
> icon and selecting [TCP/IP layer], the [services] window
DNS
ICMP (ping)
DNS functionality can be enabled by selecting the applicomIO menu-
[Protocol/Diagnostic...]-the [DNS] tab.
(1) Selects the type of resolution to be carried out.
IP Address
: the host name is obtained from the IP address.
Host Name : the IP address is obtained from the host name.
(2) Carries out a resolution.
(3) Status: Status of resolution carried out
0
: No error
33
: Response time-out exceeded
132
: Negative reply from DNS server (SERVER FAILURE, etc.)
RC700 / RC90 Option Fieldbus I/O Rev.12