Problems And Countermeasures - Epson RC700 Manual

Robot controller fieldbus i/o
Hide thumbs Also See for RC700:
Table of Contents

Advertisement

4. Troubleshooting (PROFIBUS DP)

4.2.2 Problems and Countermeasures

Light
OFF
Light
OFF
Light
OFF
Light
OFF
Light
OFF
Red
Light ON
230
Master Unit LED
BF
ST
Green
Normal
Light
communication
Blinking
Green
Ready for
Light ON
communication
Red
Communication
Light
error
Blinking
Red
Data link layer
Light ON
error
Light
Uninitialized
OFF
network
No
Physical error
Matter
Error
Description [Reference]
- Normal condition
- Normal condition
[Refer to the section 4.2.2.1 Master
Communication Error.]
- Slave disconnected from the network
(Remote I/O communication error)
- Slave not added to the network (Scan list
collation error)
- Nonstandard wiring
- No or too many terminating resistors
- Noise intrusion
[Refer to the section 4.2.2.2 Master: Data
Link Layer Error.]
- Nonstandard wiring
- Noise intrusion
[Refer to the section 4.2.2.3 Master:
Uninitialized Network.]
- Master unit power error
- Master unit configuration error
[Refer to the section 4.2.2.4 Master:
Configuration Error.]
- Nonstandard wiring
- Signal wire connection failure
- Signal wire short circuit
RC700 / RC90 Option Fieldbus I/O Rev.12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc90

Table of Contents