2. Installation
Board Installation
 Make sure that the power is turned OFF before installing/removing any boards or
connecting/disconnecting any cables. Working with the power ON is extremely
hazardous and may result in electric shock and/or malfunction of equipment.
WARNING
1.
2.
3.
4.
5.
6.
108
Configure the board address jumper (JP1) on EtherNet/IP master board.
You can install one Fieldbus master board to the PC with the EPSON RC+ 7.0
installed.
The board number should be "1".
Refer to the following table for JP1 configuration.
Short Socket
Board No.
1
Install the EtherNet/IP master board to the PCI bus of the PC with the EPSON RC+
7.0 installed. Installation method of the EtherNet/IP board to the PCI bus and how to
open the cover differ depending on the type of computers. Refer to the manuals of
each computer on how to install the board to the PCI bus.
Connect the EtherNet/IP board with the EtherNet/IP network.
Start up the PC.
Open the <applicomIO Console> installation folder and start the <applicomIO
Console> application.
Following is specified for <applicomIO Console> installation folder as default.
C:\Program Files(x86)\BoadCommunications\applicomIO\4.1
The [applicomIOR console] dialog box appears. Add the EtherNet/IP master board.
Click <Add Board>.
C0
C1
0: Short
0: Short
RC700 / RC90 Option Fieldbus I/O Rev.12
C2
0: Short