5. Make sure that the following is displayed.
6. Click <Close>.
Editing of input / output size
You can change the input/output size of DeviceNet slave board if necessary.
1. Select [Setup]-[System Configuration] and display the [System Configuration] dialog
2. Select [Inputs / Outputs]-[Fieldbus Slave]-[General].
3. Change the settings of [Input Bytes] and [Output Bytes].
4. Click <Apply>.
5. Click <Close> and the following message dialog appears.
50
Fieldbus Type
: DeviceNet
Fieldbus Slave ID : (Displays the configure switch MAC address)
Baud Rate
: (Displays the configure switch baud rate)
Input Bytes
: 32 (default setting)
Output Bytes
: 32 (default setting)
box.
In this example, both of them are changed to 20 Bytes.
The Robot Controller automatically starts rebooting.
RC700 / RC90 Option Fieldbus I/O Rev.12