2. Installation
Board Installation
 Make sure that the power is turned OFF before installing/removing any boards or
connecting/disconnecting any cables. Working with the power ON is extremely
hazardous and may result in electrical shock and/or malfunction of equipment.
WARNING
Install the board to the dedicated slot on the Robot Controller.
Reference manual:
Confirmation with EPSON RC+ 7.0
When a PROFIBUS-DP slave board is installed to the controller, it is recognized
automatically. Confirm whether EPSON RC+ 7.0 has recognized the PROFIBUS-DP
board using the following procedure.
1.
2.
3.
88
Robot Controller RC700: Maintenance 6.10 Option Board
Robot Controller RC90: Maintenance 6.8 Option Board
Select [Setup]-[System Configuration] and display the [System Configuration] dialog
box.
(2)
Select [Inputs / Outputs].
Make sure that the following are displayed in "Fieldbus Slave".
Installed
: Yes
Inputs
: 512-767 (default setting)
Outputs
: 512-767 (default setting)
(3)
RC700 / RC90 Option Fieldbus I/O Rev.12