"Encapsulation Inactivity Timeout"
Fieldbus EtherNet/IP slave module supports"Encapsulation Inactivity Timeout" which is
added by EtherNet/IP standard update.
If the EtherNet/IP master device is not supported for the standard on the above, connection
will be disconnected.
You need to change the "Encapsulation Inactivity Timeout" set value of the slave on the
EtherNet/IP master device side.
For more details, refer to 2.3.3 EtherNet/IP Master Board Installation How to change the
set value on the master side.
Electronic Information File (EDS file)
An EDS file is supplied for EtherNet/IP slave module network configuration. The file is
located in the following folder where the EPSON RC+ 7.0 is installed.
RC700 / RC90 Option Fieldbus I/O Rev.12
\EpsonRC70\Fieldbus\EtherNet/IP