Module Installation
■ Make sure that the power is turned OFF before installing/removing any modules
or connecting/disconnecting any cables. Working with the power ON is
extremely hazardous and may result in electrical shock and/or malfunction of
WARNING
equipment.
Reference manual:
Confirmation of EPSON RC+ 7.0
(1) Select [Setup]-[System Configuration] and display the [System Configuration] dialog
(2) Select [Inputs / Outputs].
(3) Make sure that the following are displayed in "Fieldbus slave".
(4) Select [Fieldbus Slave]-[General].
RC700 / RC90 Option Fieldbus I/O Rev.12
Install the module to the dedicated slot on the T3 series Manipulator.
T3 series Manipulator Setup&Operation 17. Fieldbus I/O
When the CC-Link slave module is installed to the T3 series Manipulator, it is
recognized automatically. Confirm whether EPSON RC+ 7.0 has recognized the CC-
Link board using the following procedure.
box.
(2)
Installed
: Yes
Inputs
: 512-767 (default setting)
Outputs
: 512-767 (default setting)
(4)
2. Installation
(3)
(5)
151