Epson RC700 Manual page 106

Robot controller fieldbus i/o
Hide thumbs Also See for RC700:
Table of Contents

Advertisement

2. Installation
4.
5.
6.
Editing of configuration
You can change the configuration of PROFIBUS-DP slave module if necessary.
1.
2.
3.
96
Select [Fieldbus Slave]-[General].
(4)
Make sure that the following are displayed.
Fieldbus Type
: PROFIBUS-DP
Node Address
: Configure switch node address
Type
: Byte (default setting)
Input Bytes
: 32 (default setting)
Output Bytes
: 32 (default setting)
Click <Close>.
Select [Setup]-[System Configuration] and display the [System Configuration] dialog
box.
Select [Inputs / Outputs]-[Fieldbus Slave]-[General].
Confugure a node address.
A node address from 0 to 125 is available for the PROFIBUS-DP device.
Generally, node addresses are
recommended to be configured
as shown in the table.
(5)
Node address
0
Service unit such as PG/PC
1
Operation panel such as HMI
2
Master station
3-125
DP slave station
RC700 / RC90 Option Fieldbus I/O Rev.12