4. Troubleshooting (DeviceNet)
226
Status Code
General
Protocol
45
47
53
55
65
70
79
63
66
93
99
255
Descriptions
Non-resident dialogue software.
Additional information:
Initialize the applicomIO® interface before use by
running the PcInitIO
Targeted applicomIO® card invalid or incorrectly
initialized by the function IO_Init
Synchronization problem on the line.
Additional information:
The DeviceNet master is "off line" (power supply
not detected or the CAN component of the
applicomIO® is "Bus Off")
Check the network wiring and Baud Rate.
Response time-out exceeded.
Additional information:
The device accepted the connection but did not
respond the request.
Check the device status.
Connection denied.
Additional information:
Connection to the DeviceNet master is in progress
or refused by the device.
Connection finished.
Additional information:
Duplication of MAC ID detected on the DeviceNet
network.
Modify the MAC ID of the DeviceNet master.
Profile incompatible.
Additional information:
The device does not match the configuration.
Check the device identity and the connection sizes.
Indicates that a communication error has been
encountered on serial Port.
Not enough applicomIO® interface memory.
Driver cannot be accessed.
Indicates that applicomIO® solution is already
running.
Indicates that the local input buffer was not updated
beforehand by the function IO_RefreshInput.