COMMAND CODE TITLE:
64
FUNCTION:
This command is used to define the answering system of the Automated Attendant feature.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
ST
+
64Y
+ DE
DATA TABLE:
Y
No.
MEANING
0
Answering System for
Day Mode
1
Tenant Number for Music
on Hold
2
Answering System for
Night Mode
NOTE 1:
If no tone connection is required, Dial Tone sending can be stopped by CM48 Y=2.
NOTE 2:
When providing a Night Message for Automated Attendant, the 2nd data 08 of CM30 Y=30,
31 cannot be specified for handling of busy/not available Automated Attendant destination.
AUTOMATED ATTENDANT
TENANT NUMBER
+
(2 digits)
TENANT
00-63
DATA
+
DE
+
+
(1-4 digits)
SETTING DATA
DATA
MEANING
00
DT connection
01
Hold Tone on MP card +
DT connection
02
1st Answering Message +
DT connection
03
DT connection
00
External Hold Tone
Source number assigned
09
by CM10/CM14
NONE
No data
00
DT connection
01
Hold Tone on MP card +
DT connection
02
Night Message + DT
connection
03
As per CM64 Y=0
– 497 –
EXE
: Initial Data
RELATED
COMMAND
CM30 Y=02, 03
CM48 Y=2>06
CM41 Y=0>33, 43
CM45 Y=2
CM49
CM63 Y=2
CM10/CM14>DA00-
DA09
CM48
CM44
CM30 Y=02, 03
CM41 Y=0>33, 43
CM49 Y=00>02XX,
NOTE 2
Y=02
CM64 Y=0
Continued on next page