COMMAND CODE TITLE:
00
FUNCTION:
This command is used to confirm that system data memory (RAM) area can be written-in/read-out, and
to assign the initial data to the RAM area.
PRECAUTION:
(1)
This command can only be used in off-line mode.
(2)
When this command is executed, "OK" is displayed with memory clear completed (about 10
seconds later).
(3)
If an error exists in memory, "WD ERROR" is displayed.
(4)
This command is not available with a CAT.
To clear all system data, set SW3 to "B", and depress SW1 on the MP card. In this case, the only
functional port is LEN000/LEN00000, which is assigned as a CAT.
(5)
After clearing all system data memory by CM00>1/11/12/13/14, the initial data of CM05 is set
according to the table on next page.
SYSTEM DATA MEMORY ALL CLEAR