[Cm43] Periodic Maintenance/Office Data Periodic Copy In; Backup Cpu System/D Term Ip Firmware Automatic Update/ Office Data Copy - NEC Univerge NEAX 2000 IPS Command Manual

Internet protocol server
Hide thumbs Also See for Univerge NEAX 2000 IPS:
Table of Contents

Advertisement

COMMAND CODE
43
FUNCTION:
This command is used to set the date, time and check item for periodic maintenance. The fault informa-
tion display reminds you of the time for each periodic maintenance.
[See CMEA Fault Information Display, fault kind No. 16
This command is also used to set the time for regular system data backup.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
ST
+ 43Y +
DE
+
DATA TABLE:
Y
MEANING
2 Date and time setting
for periodic mainte-
nance
3 Check item for peri-
odic maintenance
4 Time setting for office
data periodic copy
from active MP to
stand by MP in
Backup CPU system
[Series 3200 R6.1
(R6.1)]
NOTE 1:
Maximum of three minutes error may occur.
NOTE 2:
Maximum four stating time for office data periodic copy can be set to the system. If you set two or more
starting time, set the time with fifteen minutes or more interval.
TITLE:
PERIODIC MAINTENANCE/OFFICE DATA PERIODIC COPY IN BACKUP CPU
term
SYSTEM/D
IP FIRMWARE AUTOMATIC UPDATE/OFFICE DATA COPY
1ST DATA
+
DE
+
(2 digits)
(1/4/10 digits)
1ST
MEANING
DATA
00-07 Periodic maintenance 0-
7
00-03 Time setting
Page 736
2ND DATA
+
EXE
2ND DATA
YYYY MM DD HH
NONE
0
1
7
NONE
HH MM
NONE
– 432 –
]
: Initial Data
MEANING
YYYY: Year (2000-2099)
MM : Month (01-12)
DD
: Day (01-31)
HH
: Hour (00-23)
No data
Battery check
Check item No. 1
Check item No. 7
No data
HH : Hour (00-23)
MM : Minute (00-59)
0200 (2:00 a.m.)
NWA-008844-001 Rev.5.0
91ch3004.fm
JULY/01/2006
CM43

Advertisement

Table of Contents
loading

Table of Contents