NEC Univerge NEAX 2000 IPS Command Manual page 556

Internet protocol server
Hide thumbs Also See for Univerge NEAX 2000 IPS:
Table of Contents

Advertisement

COMMAND CODE TITLE:
76
Y
No.
MEANING
01
For Day Mode
02
For Night Mode
03
For Mode A
04
For Mode B
NOTE 1:
When digit conversion of the leading 2-4 digits of a DID incoming LDN is available (CM35
Y=78, Data=0), the leading 2-4 digits of the LDN should be assigned as the first data. (When
the DID incoming LDN is one digit, the digit conversion for only one digit is not available.)
NOTE 2:
If CM35 Y=143 is set to "1" for Event Based CCIS, this command must be set.
DIGIT CONVERSION ON DID CALL
1ST DATA
DATA
000-999:
Number Conver-
sion Block No.
XXXXXXXX
assigned by
CM76 Y=00/90,
CM2A Y=50-52
BBBBBXXX
NONE
2ND DATA
MEANING
X
Station number to be terminated
DXX
Change terminating system to:
D02
Trunk Line (Direct) Appearance
D03
Trunk Line (Direct) Appearance +
TAS
D04
Direct-In Termination
D09
Automated Attendant
D10
Attendant Console + TAS
D11
Attendant Console + Trunk Line
(Direct) Appearance
D12
Attendant Console + Trunk Line
Appearance + TAS
D13
TAS
D14
Attendant Console
D16
Remote Access to System (DISA)
Mate-Side Trunk No. of Virtual
Trunk
XXX: 000-255
No data
– 532 –
CM76
: Initial Data
REMARKS
CM10/CM14
NOTE 1
CM11
CM1A
CM35 Y=18,
78
CM30 Y=02,
03, 40, 41
CM30 Y=18
CM30 Y=04,
05, 42, 43
CM49 CM64
NOTE 2
Continued on next page
NWA-008844-001 Rev.5.0
91ch3005.fm
JANUARY/20/2006

Advertisement

Table of Contents
loading

Table of Contents