COMMAND CODE TITLE:
EA
2: External Alarm Kind (MJ/MN/– –)
Use of External Alarm Kind-Minor (MN), Major (MJ) or external alarm is not provided (– –) can be programmed
by CMEA Y=2. The following table shows the standard data set by the 2nd data=3 of CMEA Y=2.
FAULT KIND
(1ST)
01
System Initialized
04
MP-FP/AP communication failure
08
FP/AP card down
09
Power failure
12
CS/ZT fault occurred
16
It is a day for periodic maintenance
17
ID Code error occurred during the Key FD Activation (Center Activation)
18
FP/AP card returned to normal condition
19
Power failure returned to normal condition
20
DTI line failure
21
DCH/BRT/PRT D-channel link connection failure
22
CCH link connection failure
CCH/IPT link connection failure
24
Number of faulty trunks was more than predetermined number
[Australia
Only]
25
Number of lockout stations was more than predetermined number
(
See CM42>01)
26
DLC card down
28
SMDR output buffer memory overflow
2B
CS/ZT fault occurred
2C
LAN application fault occurred
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
CONTENT
[Series 3300 software required]
– 739 –
CMEA
ALARM KIND
MN ALARM
MN ALARM
MN ALARM
MN ALARM
– –
– –
MJ ALARM
(MJ Alarm will not be dis-
played when the Key FD
authenticated normally)
– –
– –
MN ALARM
MN ALARM
MN ALARM
MJ/MN ALARM
MN ALARM
(Fixed)
– –
MN ALARM
– –
MN ALARM
Continued on next page
NWA-008844-001 Rev.5.0