NEC Univerge NEAX 2000 IPS Command Manual page 116

Internet protocol server
Hide thumbs Also See for Univerge NEAX 2000 IPS:
Table of Contents

Advertisement

COMMAND CODE TITLE:
08
BASIC SERVICE FEATURE
073
Line Fault Detection (Metering Burst)
[Australia Only]
074
When the line disconnection or short circuit is repaired, the line
fault caused by Metering burst is automatically cleared
[Australia Only]
075
PAD control pattern
[For Large type ATTCON]
076
Warning tone is sent to C.O. line, when a station or operator
overrides a busy station connected to a C.O. line.
077
Toll Restriction-Total Digit Count for PB to PB/DP to PB Con-
nection
[Not used in North America]
078
Trunk seizure sequence when CM35 Y=83: 0
NOTE:
When the system is installed with loop-start trunks, it is
important to select the highest available trunk setting
to prevent call collisions.
085
Type of PS/WLAN Terminal No-Answer timer
088
Home PBX Numbering Plan for WCS Roaming
[For PCS]
090
Loop on control after dialing for tandem connection, when the
incoming trunk cannot receive a release signal
094
Paging access tone sent to station
095
Hook flash (break pulse) sent to Radio Paging equipment from
station
096
Hook flash (break pulse) sent to Voice Paging equipment from
station
BASIC SERVICE FEATURES
0
To provide
1
Not provided
0
Effective
1
Ineffective
0
Australia
1
Standard
0
Not sent
1
To send
0
To provide
1
Not provided
0
Highest available trunk
1
Lowest available trunk
0
As per CM41 Y=0>86
1
As per CM41 Y=0>01
0
Closed Numbering System
1
Open Numbering System
0
• When the outgoing trunk can detect
• When the outgoing trunk cannot
1
Loop on is provided
0
To send
1
Not sent
0
To send
1
Not sent
0
To send
1
Not sent
– 92 –
: Initial Data
SETTING DATA
an answer signal, loop on is not pro-
vided after dialing
detect an answer signal, loop on is
provided after dialing
Continued on next page
NWA-008844-001 Rev.5.0
CM08
91ch3001.fm
JULY/01/2006