Configure Frequency Output Fault Action; Options For Frequency Output Mode - Emerson Micro Motion 5700 Configuration And Use Manual

Transmitters with configurable outputs
Hide thumbs Also See for Micro Motion 5700:
Table of Contents

Advertisement

Integrate the meter with the control system
March 2019

Options for Frequency Output Mode

Option
Independent
In-Phase
50% duty cycle
90° Phase Shift
50% duty cycle
–90° Phase Shift
50% duty cycle
180° Phase Shift
50% duty cycle
(1)
Quadrature
50% duty cycle
(1)
Quadrature mode is used only for specific Weights & Measures applications where required by law.

8.4.5 Configure Frequency Output Fault Action

Display
Menu > Configuration > Inputs/Outputs > Channel x > Frequency Output x > Fault Action
ProLink III
Device Tools > Configuration > I/O > Outputs > Frequency Output x > Fault Action
Field Communicator
Configure > Manual Setup > Inputs/Outputs > Channel x > Frequency Output x > FOxFault Settings > FOx
Fault Action
Frequency Output Fault Action controls the behavior of the Frequency Output if the transmitter detects a
fault condition.
Important
The fault action is implemented only if Alert Severity is set to Failure. If Alert Severity is set to any other
option, the fault action is not implemented.
154
Process condition and effect
No relationship between the two
outputs
Signals are aligned
Frequency Output 1 leads
Frequency Output 2 by 90°
Frequency Output 1 lags
Frequency Output 2 by 90°
Frequency Output 1 leads
Frequency Output 2 by 180°
Forward flow, as determined by the
setting of Sensor Direction and
actual flow direction
Frequency Output 1 leads
Frequency Output 2 by 90°
Reverse flow, as determined by the
setting of Sensor Direction and
actual flow direction
Frequency Output 1 lags
Frequency Output 2 by 90°
Fault
Frequency Output 1 performs the
configured fault action
Frequency Output 2 is driven to 0
Channel behavior
Frequency Output 1
Frequency Output 2
Frequency Output 1
Frequency Output 2
Frequency Output 1
Frequency Output 2
Frequency Output 1
Frequency Output 2
Frequency Output 1
Frequency Output 2
Frequency Output 1
Frequency Output 2
Frequency Output 1
Frequency Output 2
Frequency Output 1
Frequency Output 2
Micro Motion Model 5700 Transmitters with Configurable Outputs
Configuration and Use Manual
MMI-20025166