12.4.2 Start, stop, and reset totalizers using ProLink III
You can start and stop each totalizer or inventory independently. You can start and stop all totalizers as a
group. You can reset each totalizer or inventory independently. You can reset all totalizers as a group. You can
reset all inventories as a group.
When a totalizer or inventory is started, its value increases or decreases depending on the interaction of the
flow direction parameters. It continues tracking flow until it is stopped.
When a totalizer or inventory is reset, its value is set to 0. You can reset a totalizer or inventory while it is
started or while it is stopped.
Prerequisites
To reset an inventory using ProLink III, this function must be enabled. To enable inventory reset using ProLink
III, choose Tools > Options and enable Reset Inventories from ProLink III. Note that this affects only ProLink
III. Resetting inventories using other tools is not affected.
Procedure
To start or stop a single totalizer:
a) Choose Device Tools > Totalizer Control > Totalizers.
b) Scroll to the totalizer that you want to start or stop, and click Start or Stop.
To start or stop a single inventory:
a) Choose Device Tools > Totalizer Control > Inventories.
b) Scroll to the inventory that you want to start or stop, and click Start or Stop.
To start or stop all totalizers as a group:
a) Choose Device Tools > Totalizer Control > Totalizers or Device Tools > Totalizer Control >
Inventories.
b) Click Start All Totals or Stop All Totals.
To reset a single totalizer:
a) Choose Device Tools > Totalizer Control > Totalizers.
b) Scroll to the totalizer that you want to reset, and click Reset.
To reset a single inventory:
a) Choose Device Tools > Totalizer Control > Inventories.
b) Scroll to the inventory that you want to reset, and click Reset.
To reset all totalizers as a group:
a) Choose Device Tools > Totalizer Control > Totalizers.
b) Click Reset All Totals.
To reset all inventories as a group:
a) Choose Device Tools > Totalizer Control > Inventories.
b) Click Reset All Inventories.