Api Tables Supported By The Api Referral Application - Emerson Micro Motion 5700 Configuration And Use Manual

Transmitters with configurable outputs
Hide thumbs Also See for Micro Motion 5700:
Table of Contents

Advertisement

Configuration and Use Manual
MMI-20025166
Verify that the host is writing to the correct register in memory, using the correct data type.

5.1.4 API tables supported by the API referral application

The API tables listed here are supported by the API referral application.
Table 5-1: API tables, process fluids, measurement units, and default reference values
Referred
Process fluid
density
Generalized crude
5A
and JP4
23A
53A
Generalized
5B
products (gasoline,
jet fuel, aviation fuel,
23B
kerosene, heating
oils, fuel oils, diesel,
gas oil)
53B
Liquids with a
N/A
constant density
N/A
base or known
thermal expansion
N/A
(5)
coefficient
Lubricating oils
5D
23D
53D
NGL (natural gas
23E
liquids) and LPG
53E
(liquid petroleum
gas)
Configuration and Use Manual
API tables
(1)
(calculations)
Referred density
CTL or
(API): unit and
(2)
(3) (4)
CTPL
range
6A
Unit: °API
Range: 0 to 100 °API
24A
Unit: SGU
Range: 0.6110 to
1.0760 SGU
54A
Unit: kg/m
Range: 610 to
1075 kg/m³
6B
Unit: °API
Range: 0 to 85 °API
24B
Unit: SGU
Range: 0.6535 to
1.0760 SGU
54B
Unit: kg/m
Range: 653 to
1075 kg/m³
6C
Unit: °API
24C
Unit: SGU
54C
Unit: kg/m³
6D
Unit: °API
Range: −10 to
+40 °API
24D
Unit: SGU
Range: 0.8520 to
1.1640 SGU
54D
Unit: kg/m³
Range: 825 to
1164 kg/m³
24E
Unit: SGU
54E
Unit: kg/m³
Configure process measurement applications
Default
Default
reference
reference
temp
pressure
60 °F
0 psi (g)
60 °F
0 psi (g)
3
15 °C
0 kPa (g)
60 °F
0 psi (g)
60 °F
0 psi (g)
3
15 °C
0 kPa (g)
60 °F
0 psi (g)
60 °F
0 psi (g)
15 °C
0 kPa (g)
60 °F
0 psi (g)
60 °F
0 psi (g)
15 °C
0 kPa (g)
60 °F
0 psi (g)
15 °C
0 psi (g)
March 2019
API standard
API MPMS 11.1
API MPMS 11.1
API MPMS 11.1
API MPMS 11.1
API MPMS 11.2.4
69

Advertisement

Table of Contents
loading