Output Saturated; Process Aberration - Emerson Micro Motion 5700 Configuration And Use Manual

Transmitters with configurable outputs
Hide thumbs Also See for Micro Motion 5700:
Table of Contents

Advertisement

Configure device options and preferences
March 2019
Table 7-11: Output Fixed conditions
Name
[122] Discrete Output 3 Fixed
Frequency Output 2 Fixed
mA Output 3 Fixed

Output Saturated

Default severity: Out of Speculation
Severity configurable: Yes
Fault Timeout applicable: No
Table 7-12: Output Saturated conditions
Name
[100] mA Output 1 Saturated
[110] Frequency Output 1 Saturated
[113] mA Output 2 Saturated
Frequency Input Saturated
Frequency Output 2 Saturated
mA Output 3 Saturated

Process Aberration

Default severity: Out of Speculation
Severity configurable: Yes
Fault Timeout applicable: Yes
Table 7-13: Process Aberration conditions
Name
[105] Two-Phase Flow
[115] External Input Error
[116] Temperature Overrange (API referral)
[117] Density Overrange (API referral)
[121] Extrapolation Alert (Concentration)
[123] Pressure Overrange (API referral)
[138] TBR Active
Batch Time Out
Moderate Two-Phase Flow
Severe Two-Phase Flow
132
(continued)
Micro Motion Model 5700 Transmitters with Configurable Outputs
Configuration and Use Manual
MMI-20025166
Ignorable
No
No
No
Ignorable
Yes
Yes
Yes
Yes
Yes
Yes
Ignorable
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes