Technical Data - Festo Field Rheostat EduTrainer 8036772 Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

7 Technical Data

Technical data
Input voltage, L1 / L2 / L3/ N
Input frequency
Max. current consumption, L1 / L2 / L3
/ N
Protection class
Overvoltage category
Degree of contamination
Electrical connections
Operating temperature range
Max. relative humidity
Protection
Device operation
Dimensions
(H x W x D in mm)
Weight
Technical data for Rheostat R1
Max. short-time power (120 s)
Area 1
Area 2
Certifications
CE marking per
8036771
© Festo Didactic
3 x 400 V AC ±10%
50 ... 60 Hz
16 A, must be limited by back-up fuse
1, operation with protective grounding
II, operation in building installations
2, laboratory environment
Safety laboratory cables per EN 61010-031, min. conductor cross-section: 1 sq. mm
5 ... 40° C / 100%
80 %
IP 20 (not attached to the mounting frame)
Use only indoors, max. altitude: 2000 m above sea level
297 x 133 x140
2 kg
150 W
Resistance
Maximum
range
current
0 ... 450 Ω
0.5 A
450 ... 1500 Ω
0.25 A
Low Voltage Directive
RoHS Directive
Maximum
Continuous
voltage
power
225 V
112.5 W
375 V
93.75 W
Short-time power
(120 s)
150 W
125 W
25

Advertisement

Table of Contents
loading

Table of Contents