Safety Engineering Characteristics; Switch-Through Pressure/Filling Time - Festo MS6N-SV E-ASIS Series Assembly Installation Safety Instructions

Soft start/quick exhaust valve
Hide thumbs Also See for MS6N-SV E-ASIS Series:
Table of Contents

Advertisement

Technical data
14.4

Safety engineering characteristics

Type
Conforms to standard
Safety function
Performance Level (PL)
Safety Integrity Level (SIL)
Service-life value B10
PFH
CCF measures
Note for
Forced switch on/off
CE marking
 Declaration of conform-
è
ity
Type test
Tab. 15 Safety engineering characteristics
In addition to the system reaction time of max. 40 ms, the reaction times of the safe AS-Interface
sensor slave must also be added.
The reaction times to be added can be found in the technical data of the slaves, sensors and actuat-
ors.
14.5

Switch-through pressure/filling time

The flow control screw in the cover generates a gradual pressure build-up of outlet pressure p2. The
pressure rise can be adjusted by turning the flow control screw. If the outlet pressure p2 has reached
approx. 50 % of the operating pressure p1, the valve opens and full operating pressure p1 is applied
at the outlet.
22
MS6-SV- ... -E-ASIS
EN ISO 13849-1:2008-06
EN ISO 13849-2:2008-06
Exhausting
Exhausting: category 4, PL e
Exhausting: SIL 3
[million
0.25
SP]
4.51 10E-9
Maintain operating pressure limits
Comply with temperature range
Comply with vibration/shock limits
Comply with compressed air quality
Switching frequency at least 1/month
In accordance with EU Machinery Directive
In accordance with EU EMC Directive
The functional safety engineering of the product has been
certified by an independent testing laboratory
examination certificate (www.festo.com)
MS6N-SV- ... -E-ASIS
Festo — MS6(N)-SV-...-E-ASIS — 2019-05a
 EC-type
è

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms6-sv e-asis series

Table of Contents