12.13

System sampling times

12.13.1

Description

The software functions installed in the system are executed cyclically at different sampling
times (p0115, p0799, p4099).
The sampling times of the functions are automatically pre-assigned when configuring the
drive unit.
The settings are based on the selected mode (vector/servo), the number of connected
components, and the functions activated.
The sampling times can be adjusted using parameter p0112 (sampling times, pre-setting
p0115), p0113 (pulse frequency, minimum selection) or directly using p0115.
For p0092 = 1, the sampling times are pre-assigned so that isochronous operation together
with a control is possible. If isochronous operation is not possible due to incorrect sampling
time settings, then an appropriate message is output (A01223, A01224). Before the
automatic configuration, parameter p0092 must be set to "1" in order that the sampling times
are appropriately pre-set.
Note
Any change to the preset sampling times should only be performed by experts.
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
Basic information about the drive system
12.13 System sampling times
629