Vector control

4.15 Instructions for commissioning induction motors (ASM)

4.15
Instructions for commissioning induction motors (ASM)
Equivalent circuit diagram for vector induction motor and cable
Figure 4-23
Equivalent circuit diagram for induction motor and cable
Induction motors, rotating
The following parameters can be entered in STARTER during the commissioning phase:
Table 4- 3
Motor data rating plate
Parameter
p0304
p0305
p0307
p0308
p0310
p0311
p0335
158
Description
Rated motor voltage
Rated motor current
Rated motor power
Rated motor power factor
Rated motor frequency
Motor rated speed
Motor cooling type
If this value is not known, a "0" can also
be entered. Using this value, the stator
leakage inductance can be more
precisely calculated (p0356, p0357).
-
-
-
-
-
-