Siemens SINAMICS S120 Function Manual page 184

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Vector V/f control (r0108.2 = 0)
5.1 Introduction
Table 5- 1
V/f characteristic (p1300)
Parameter
Meaning
values
0
Linear characteristic
1
Linear characteristic
with flux current control
(FCC)
2
Parabolic characteristic Characteristic that takes into account
3
Programmable
characteristic
184
Standard (w/o voltage boost)
Characteristic that compensates for
voltage losses in the stator resistance
for static / dynamic loads (flux current
control FCC).
This is particularly useful for small
motors, since they have a relatively
high stator resistance.
the motor torque curve (e.g. fan/pump).
a) Quadratic characteristic (f
characteristic)
b) Energy saving because the low
voltage also results in small currents
and drops.
Characteristic that takes into account
motor/machine torque curve (e.g.
synchronous motor).
Application / property
2
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
Drive functions

Advertisement

Table of Contents
loading

Table of Contents