Basic functions
6.9 Armature short-circuit brake, internal voltage protection, DC brake
Internal armature short-circuit (synchronous motors)
The internal armature short-circuit is activated via the parameter p1231 = 4. It can be
triggered via an input signal p1230 (signal = 1) or a fault response.
Both types of activation are equivalent and are no longer distinguished during the braking
operation, in contrast to DC brake (see paragraph "DC brake").
When the internal armature short-circuit protection is activated, the same mechanism as with
the integrated voltage protection will short-circuit one of the half-bridges in the Motor Module.
After completion of the internal armature short-circuit, it is continued rotor-oriented.
r0046.4
p1230
(1)
Figure 6-4
Internal armature short-circuit
214
1
r0046.20
&
F07907
M
3
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
2000 µs
p1231 = 4
~
Drive functions