Siemens SINAMICS S120 Function Manual page 565

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

● Save parameters - device and all drives
● Save the parameters with STARTER
Resetting parameters
The parameters can be reset to the factory setting as follows:
● Reset parameters - current drive object
● Reset parameters - all parameters drive object "Control Unit"
Access level
The parameters are subdivided into access levels. The SINAMICS S120/S150 List Manual
specifies the access level in which the parameter is displayed and can be changed. The
required access levels 0 to 4 can be set in p0003.
Table 12- 1
0 User-defined
1 Standard
2 Extended
3 Expert
4 Service
Note
Parameter p0003 is CU-specific (belongs to Control Unit).
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
p0977 = 1; automatically reset to 0
See "Copy RAM to ROM" function
p0970 = 1; automatically reset to 0
p0009 = 30 parameter reset
p0976 = 1; automatically reset to 0
Access levels
Access level
Parameters from the user-defined list (p0013)
Parameters for the simplest operator functions (e.g. p1120 = ramp-function
generator ramp-up time).
Parameters to handle the basic functions of the device.
Expert knowledge is already required for this parameter (e.g. knowledge
about BICO parameterization).
Please contact your local Siemens office for the password for parameters
with access level 4 (Service). It must be entered into p3950.
Basic information about the drive system
Remark
12.1 Parameter
565