Requirements
To be able to back up SMI EEPROM data to a memory card, the following conditions must
be fulfilled:
● SINAMICS firmware version as of 2.5 on CU.
● STARTER or SCOUT is connected online to the CU.
● The drive system is fully commissioned (the target topology contains only component
Backup methods
The data of the SINAMICS Sensor Module Integrated can be saved retentively on the
memory card.
● Back up the data of all SINAMICS Sensor Modules Integrated with p4692 = 1
● Selective backup of the data of one SINAMICS Sensor Module Integrated:
The data are saved in two files on the memory card.
● for motor data: SMIn0xz1.bin
● for encoder data: SMIn0xz2.bin
Example:
The two files of a SINAMICS Sensor Module Integrated with the component number 7 are
saved in the following path on a CU3x0:
/USER/SINAMICS/DATA/SMI_DATA/C007/...
Back up the data of all SMIs (p4692=1)
SMI data backup is started with CU parameter "Back up data of all SMIs" p4692=1. When all
the data have been backed up, parameter p4962 is reset to 0 automatically.
Data can be backed up only for SMIs which are displayed in the "Actual topology".
602
numbers less than 200).
– Enter the component number (stored in p0141 and displayed in the target topology) in
p4690.
– Activate the data backup via p4691 = 1.
"...n..." indicates the version of the SINAMICS Sensor Module Integrated:
– "...1..." for SMI10
(encoder evaluation for resolver),
– "...2..." for SMI20
(encoder evaluation for incremental encoder sin/cos 1 Vpp and absolute encoder
Endat)
The dummy "z" stands for data formats b (block structure) or e (EFS file system).