Function modules
7.9 Basic positioner
3
0
EDS0
4
0
EDS0
5
1
EDS4
6
2
EDS5
7
3
EDS0
Is newly initiated means: For absolute encoders, the absolute value is newly read out, and for
1)
incremental encoders, a restart will take place as after POWER ON.
For incremental encoders, r2684.11 ("Reference point set") is reset, and for
2)
absolute encoders, also the status of the adjustment (p2507).
For incremental encoders, r2684.11 ("Reference point set") is reset, and for
3)
absolute encoders, the adjustment status (p2507) is not reset because the
EDS differs from the original one.
xxx, yyy, zzz: different mechanical conditions
Function diagrams (see SINAMICS S120/S150 List Manual)
● 3612 Referencing
● 3614 Flying referencing
Overview of important parameters (see SINAMICS S120/S150 List Manual)
● p2596 BI: EPOS set reference point
● p2597 BI: EPOS referencing type selection
● p2598 CI: EPOS reference point coordinate, signal source
● p2599 CO: EPOS reference point coordinate value
● p2600 EPOS reference point approach, reference point offset
302
EDS1
EDS2
EDS3
EDS2
EDS1
EDS2
EDS6
EDS7
EDS1
EDS2
encoder_
xxx
disabled
2
encoder_
xxx
disabled
2
encoder_
xxx
disabled
1
encoder_
zzz
disabled
1
encoder_
xxx
disabled
1
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
Pulse inhibit: Position
actual value conditioning is
newly initiated
and
1)
reference bit
is reset.
3)
Operation:
Fault message is
generated. Position actual
value
preprocessing is newly
initiated
1)
and reference bit
is
3)
reset.
MDS switching alone
during pulse inhibit or
operation has no effect
Drive functions