Mitsubishi Electric MELSEC iQ-R-R00CPU User Manual page 590

Melsec iq-r series cpu module application user's manual
Table of Contents

Advertisement

■In SAFETY MODE
The following table lists file operations which are available for each file type in SAFETY MODE.
: Available, : Not available, : N/A
File type
Standard program
Standard FB file
Standard CPU parameter
System parameter
Standard module parameter
Module extension parameter
Module-specific backup parameter
Memory card parameter
Device comment
Device initial value
Standard global label setting file
Label initial
Global label initial
value file
value file
Local label initial
value file
File register
Event history
Device data storage file
General-purpose data
Remote password
Safety program
Safety FB file
*3
Safety CPU parameter
Safety module parameter
Safety global label setting file
Standard/safety shared label setting
file
*1 To write files to the programmable controller, use the write function when the operating status of the SIL2 Process CPU is STOP. When
the operating status is RUN, use the online change function. When the SIL2 Process CPU operating status is RUN, only the standard
programs registered in the CPU parameter can be written to the programmable controller.
*2 Operation is possible only when the operating status of the SIL2 Process CPU is STOP/PAUSE. If any file operation is performed in the
RUN state, the operating status of the SIL2 Process CPU is changed by the remote STOP function, and then the operation continues.
*3 This parameter relates to safety control inside the CPU parameters. ( Page 936 Safety CPU parameters)
This item is yellow in the engineering tool CPU parameters.
*4 Writing is possible in file units, however, it is not possible to select files together with parameter files or files relating to safety and then
write to the programmable controller CPU. If writing in file units, write after clearing the selection of other parameter files or files relating
to safety, or write after switching to TEST MODE.
*5 Operation is possible only when the operating status of the SIL2 Process CPU is STOP/PAUSE. A communication error occurs when
the file is operated in the RUN state.
35 BASIC CONCEPT
588
35.11 Memory Specifications
Operation using engineering tool
Write
Read
Delete
*1*4
*2
*2*4
*2
*2
*2
*5
*2
*2
*2
*2
*2*4
*2
*2
*2
*2
*2
*2
Operation with SLMP and FTP
server function
Write
Read
Delete
Operation with
instructions in
standard programs
Write
Read

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents