Menu items and setting methods

This section describes the operation method and/or setting windows of CPU Module Logging Configuration Tool.
Menu structure
The following table describes the menu structure of CPU Module Logging Configuration Tool.
Menu item
Project
New
Open
Save
Save As
Read Logging Setting from Memory Card (SD)
Write Logging Setting into Memory Card (SD)
Recent Files
Read GX Works3 Project
Exit
Edit
Delete Data Logging Setting
Copy and Add Data Logging Setting
Batch Data Insertion
Cut Setting Item
Copy Setting Item
Paste Setting Item
Paste device/label copied in other application software
Insert Copied Setting Item
Insert device/label copied in other application software
Insert Cut Setting Item
Delete Setting Item
Move Setting Item Upward
Move Setting Item Downward
Device Batch Replacement
View
Switch Display Language
Online
Transfer Setup
Read Logging Setting
Write Logging Setting
Delete Logging Setting
Logging Status and Operation
Logging File Operation
Data Logging File Transfer Status
Tool
Start GX LogViewer
Help
Open Manual
Connection to MITSUBISHI ELECTRIC FA Global
Website
About Configuration tool
Description
Create a new project.
Open a stored project file.
Overwrite an edited project to the file and saves it.
Save an edited project with a new file name.
Read the data logging setting written in the SD memory card attached to the
personal computer.
Write the settings being edited in a format with which the CPU module can
operate. Once the settings is directly written into an SD memory card attached to
the personal computer and then the SD memory card is mounted onto the CPU
module, the data logging starts.
Open a recently used file.
Import a project of the engineering tool which is the read source for the label.
Exit CPU Module Logging Configuration Tool.
Remove the data logging setting selected in the Edit item tree.
Copy and add the data logging setting selected in the Edit item tree.
Configure the multiple setting items at once.
Cut the setting with a table format.
Copy the setting with a table format.
Paste the setting with a table format.
Paste a device/label which is copied in another application into a line selected.
(Existing data in the line are overwritten and erased.)
Paste the copied setting with a table format.
Paste a device/label which is copied in another application into a line selected
and shift down existing data in the selected line and below.
Paste the cut setting with a table format.
Remove the setting with a table format.
Move up a setting item.
Move down a setting item.
Replace devices for all the settings.
Change the display language for menus and so on.
Configure the communication setting used for connection to the CPU module.
Read the setting from the CPU module.
Write the setting to the CPU module.
Remove the setting data from the CPU module.
Check the data logging status.
Connect to the CPU module and read or remove the files in the attached SD
memory card or data memory.
The transfer status of the data logging file is displayed.
Launch GX LogViewer.
e-Manual Viewer opens and its manual is displayed.
The Mitsubishi Electric Corporation FA website is displayed.
The product information is displayed.
Appendix 13 How to Use CPU Module Logging Configuration Tool