System information

The following is the list of special register areas relating to the system information.
No.
Name
SD160
Firmware version
SD200
Status of switch
SD201
LED status
SD203
Operating status of
CPU
SD205
Safety operation
mode
SD206
Pair version
SD210
Clock data
SD211
SD212
SD213
SD214
SD215
SD216
SD218
Time zone setting
value
APPX
846
Appendix 5 List of Special Register Areas
Data stored
Details
Firmware version
The firmware version is stored.
Status of CPU
The switch status of the CPU module is stored as follows:
switch
0: RUN, 1: STOP
CPU-LED state
This register stores the information that indicates LED status (0: off, 1:
on, 2: flashing) of the CPU module in the following bit patterns.
b15
(8)
(1) READY
(2) ERROR
(3) PROGRAM RUN
(4) USER
(5) BATTERY
(6) CARD READY
(7) CARD ACCESS
(8) FUNCTION
• For the R00CPU, (5), (6), and (7) are fixed to 0.
• For the R01CPU and R02CPU, (5) is fixed to 0.
Operating status of
The operating status of the CPU module is stored as follows:
CPU
0: RUN, 2: STOP, 3: PAUSE
Safety operation
The safety operation mode is stored. (The applicable bit turns on.)
mode
b15
(1) TEST MODE
(2) SAFETY MODE
(3) SAFETY MODE (wait-for-restart)
Pair version
The pair version of the SIL2 Process CPU or Safety CPU is stored in
decimal notation.
Clock data (year)
The year value (four digits) of the clock data is stored as a BIN code.
Clock data (month)
The month value of the clock data is stored as a BIN code.
Clock data (day)
The day value of the clock data is stored as a BIN code.
Clock data (hour)
The hour value of the clock data is stored as a BIN code.
Clock data (minute)
The minute value of the clock data is stored as a BIN code.
Clock data (second)
The second value of the clock data is stored as a BIN code.
Clock data (day of
The day of the week value of the clock data is stored as a BIN code. (0:
the week)
Sun, 1: Mon, 2: Tue, 3: Wed, 4: Thu, 5: Fri, 6: Sat)
Time zone (in
The time zone setting value specified in the parameter is stored in
minutes)
increments of minutes.
Example: when the setting value of the time zone is "UTC+9," the result
of the following equation is stored into SD218: 9  60 (minutes) = 540.
b12
b11
b8
b7
(7)
(6)
(5)
(4)
(3)
b3
0
Set by
(setting
timing)
S (Initial)
S (Switch
change)
S (Status
change)
b4 b3
b0
(2)
(1)
S (Every
END)
S (Status
change)
b2
b1
b0
1/0
1/0
1/0
(3)
(2)
(1)
S (Initial)
S/U
(Request)
S/U
(Request)
S/U
(Request)
S/U
(Request)
S/U
(Request)
S/U
(Request)
S/U
(Request)
S (Initial)
CPU
*1
Rn
*5
RnP
*4
RnSF
ALL
ALL
ALL
RnPSF
RnSF
RnPSF
RnSF
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL