Mitsubishi Electric MELSEC iQ-R-R00CPU User Manual page 865

Melsec iq-r series cpu module application user's manual
Table of Contents

Advertisement

No.
Name
SD1217
Data logging setting
No.1
Data logging file
transfer error cause
SD1220
Data logging setting
to
No.2
SD1227
SD1230
Data logging setting
to
No.3
SD1237
SD1240
Data logging setting
to
No.4
SD1247
SD1250
Data logging setting
to
No.5
SD1257
SD1260
Data logging setting
to
No.6
SD1267
SD1270
Data logging setting
to
No.7
SD1277
SD1280
Data logging setting
to
No.8
SD1287
SD1290
Data logging setting
to
No.9
SD1297
SD1300
Data logging setting
to
No.10
SD1307
*1 The CPU module where this function can be used supports these special register areas.
*2 These CPU modules do not support Data logging file transfer error causes for the data logging settings No.2 to No.10 (SD1227,
SD1237, SD1247, SD1257, SD1267, SD1277, SD1287, SD1297, SD1307).
Data stored
Details
Data logging file
An error cause that is detected last in the data logging file transfer
transfer error cause
function or a transferring of data logging files to the data memory is
stored.
0: No error
Other than 0:For details on the values stored when an error occurs,
refer to the list of error codes. ( Page 703 List of error
codes)
This register is cleared to 0 when data logging is started.
Same configuration
Data configuration is the same as the setting No.1 (SD1210 to
as the setting No.1
SD1217).
Same configuration
Data configuration is the same as the setting No.1 (SD1210 to
as the setting No.1
SD1217).
Same configuration
Data configuration is the same as the setting No.1 (SD1210 to
as the setting No.1
SD1217).
Same configuration
Data configuration is the same as the setting No.1 (SD1210 to
as the setting No.1
SD1217).
Same configuration
Data configuration is the same as the setting No.1 (SD1210 to
as the setting No.1
SD1217).
Same configuration
Data configuration is the same as the setting No.1 (SD1210 to
as the setting No.1
SD1217).
Same configuration
Data configuration is the same as the setting No.1 (SD1210 to
as the setting No.1
SD1217).
Same configuration
Data configuration is the same as the setting No.1 (SD1210 to
as the setting No.1
SD1217).
Same configuration
Data configuration is the same as the setting No.1 (SD1210 to
as the setting No.1
SD1217).
Set by
(setting
timing)
S (Error)
Same
configuration
as the setting
No.1
Same
configuration
as the setting
No.1
Same
configuration
as the setting
No.1
Same
configuration
as the setting
No.1
Same
configuration
as the setting
No.1
Same
configuration
as the setting
No.1
Same
configuration
as the setting
No.1
Same
configuration
as the setting
No.1
Same
configuration
as the setting
No.1
Appendix 5 List of Special Register Areas
CPU
*1
Rn
*1
Rn
*2
RnP
*2
RnSF
*1
Rn
*2
RnP
*2
RnSF
*1
Rn
*2
RnP
*2
RnSF
*1
Rn
*2
RnP
*2
RnSF
*1
Rn
*2
RnP
*2
RnSF
*1
Rn
*2
RnP
*2
RnSF
A
*1
Rn
*2
RnP
*2
RnSF
*1
Rn
*2
RnP
*2
RnSF
*1
Rn
*2
RnP
*2
RnSF
APPX
863

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents