Data logging function processing time

This section describes the processing time taken to store the data when executing the data logging function. (The values
shown in the tables below are the minimum time values that allow the CPU module to collect data without missing any data
while the continuous logging is executed.)
When the file format is Unicode text file
■When a global device or global label is specified
The following table lists the collection intervals at which data can be collected under the following conditions.
• Scan time = 1.5ms (up to 3ms)
• Internal buffer capacity setting = 128K bytes per setting (default setting)
• Collection setting = Time specification (data collection at time interval)
• Data setting = Data register (D) (Data-type: word-signed (decimal number type))
• Output setting = Day/time column (output format is default) and index column are outputted.
• Save setting = file switching timing: 1024K bytes (when the data storage destination memory is the function memory) or
10000 records (when the data storage destination memory is the SD memory card), operation when the number of saved
files exceeded: overwriting
• When the data storage destination memory is the SD memory card, functions that require access to files in the SD memory
card except for the data logging function are not active.
• The default setting value is used for the file transfer server setting of the CPU Module Logging Configuration Tool (however,
the IP address, login user name, and password can be customized).
• Parameters are used only for required settings that can be connected to the FTP server (IP address settings of the module
parameter only) and default setting values are used for other settings.
*1 3ms (to 4.5ms) for the Process CPU (redundant mode)
Number of points
File transfer
(8 points  1
8
Not performed
points
setting)
Performed
(16 points  1
16
Not performed
points
setting)
Performed
64
(64 points  1
Not performed
points
setting)
Performed
*1
Collection interval at which data can be collected
When the
When the SD memory card is used
function
NZ1MEM-2GBSD
memory is
Programmable
used
controller CPU
1.0ms
No file deletion
1.0ms
specification at
transfer
completion
File deletion
1.0ms
1.0ms
specification at
transfer
completion
1.0ms
No file deletion
1.0ms
specification at
transfer
completion
File deletion
1.0ms
1.0ms
specification at
transfer
completion
1.0ms
No file deletion
1.0ms
specification at
transfer
completion
File deletion
1.0ms
1.0ms
specification at
transfer
completion
NZ1MEM-4/8/16GBSD
Process CPU,
Programmable
Safety CPU
controller CPU
1.0ms
1.0ms
1.0ms
1.0ms
1.0ms
1.0ms
1.0ms
1.0ms
2.0ms
2.0ms
2.0ms
3.0ms
Appendix 9 Processing Time
A
Process CPU,
Safety CPU
1.0ms
2.0ms
5.0ms
APPX
913

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents