No.
Name
SD1890
Current safety cycle
processing time
SD1891
SD1892
Minimum safety cycle
processing time
SD1893
SD1894
Maximum safety
cycle processing time
SD1895
SD1903
Total standard/safety
shared label usage
capacity
SD1904
Start I/O number of
the CC-Link IE Field
Network safety
communication target
station (1st module)
SD1905
Start I/O number of
the CC-Link IE Field
Network safety
communication target
station (2nd module)
SD1906
Start I/O number of
the CC-Link IE Field
Network safety
communication target
station (3rd module)
SD1907
Start I/O number of
the CC-Link IE Field
Network safety
communication target
station (4th module)
SD1908
Start I/O number of
the CC-Link IE Field
Network safety
communication target
station (5th module)
SD1909
Start I/O number of
the CC-Link IE Field
Network safety
communication target
station (6th module)
SD1910
Start I/O number of
the CC-Link IE Field
Network safety
communication target
station (7th module)
SD1911
Start I/O number of
the CC-Link IE Field
Network safety
communication target
station (8th module)
Data stored
Details
Current safety cycle
• The current safety cycle processing time is stored. (The time is
processing time (unit:
measured in microseconds (s).)
ms)
SD1890: The ms part is stored. (Range: 0 to 65535)
SD1891: The s part is stored. (Range: 0 to 999)
Current safety cycle
• The measurement is stored even when the status is STOP.
processing time (unit:
s)
Minimum safety cycle
• The minimum safety cycle processing time is stored. (The time is
processing time (unit:
measured in microseconds (s).)
ms)
SD1892: The ms part is stored. (Range: 0 to 65535)
SD1893: The s part is stored. (Range: 0 to 999)
Minimum safety cycle
• The measurement is stored even when the status is STOP.
processing time (unit:
s)
Maximum safety
• The maximum safety cycle processing time is stored. (The time
cycle processing time
is measured in microseconds (s).)
(unit: ms)
SD1894: The ms part is stored. (Range: 0 to 65535)
SD1895: The s part is stored. (Range: 0 to 999)
Maximum safety
• The measurement is stored even when the status is STOP.
cycle processing time
(unit: s)
Total standard/safety
The total usage capacity for labels defined in the standard/safety
shared label usage
shared label setting file is stored in 4-word units.
capacity (unit: words)
0 to FFH: Start I/O
• The value obtained by dividing the start I/O number of the station
number
targeted for CC-Link IE Field Network safety communications by
FFFFH: Not set
16 is stored.
• When the safety communication function is not used, FFFFH is
stored.
0 to FFH: Start I/O
• The value obtained by dividing the start I/O number of the station
number
targeted for CC-Link IE Field Network safety communications by
FFFFH: Not set
16 is stored.
• When the safety communication function is not used, FFFFH is
stored.
0 to FFH: Start I/O
• The value obtained by dividing the start I/O number of the station
number
targeted for CC-Link IE Field Network safety communications by
FFFFH: Not set
16 is stored.
• When the safety communication function is not used, FFFFH is
stored.
0 to FFH: Start I/O
• The value obtained by dividing the start I/O number of the station
number
targeted for CC-Link IE Field Network safety communications by
FFFFH: Not set
16 is stored.
• When the safety communication function is not used, FFFFH is
stored.
0 to FFH: Start I/O
• The value obtained by dividing the start I/O number of the station
number
targeted for CC-Link IE Field Network safety communications by
FFFFH: Not set
16 is stored.
• When the safety communication function is not used, FFFFH is
stored.
0 to FFH: Start I/O
• The value obtained by dividing the start I/O number of the station
number
targeted for CC-Link IE Field Network safety communications by
FFFFH: Not set
16 is stored.
• When the safety communication function is not used, FFFFH is
stored.
0 to FFH: Start I/O
• The value obtained by dividing the start I/O number of the station
number
targeted for CC-Link IE Field Network safety communications by
FFFFH: Not set
16 is stored.
• When the safety communication function is not used, FFFFH is
stored.
0 to FFH: Start I/O
• The value obtained by dividing the start I/O number of the station
number
targeted for CC-Link IE Field Network safety communications by
FFFFH: Not set
16 is stored.
• When the safety communication function is not used, FFFFH is
stored.
Set by
(setting
timing)
S (Status
change)
S (Status
change)
S (Status
change)
S (Status
change)
S (Initial)
S (Initial)
S (Initial)
S (Initial)
S (Initial)
S (Initial)
S (Initial)
S (Initial)
Appendix 5 List of Special Register Areas
CPU
RnPSF
RnSF
RnPSF
RnSF
RnPSF
RnSF
RnPSF
RnSF
RnPSF
RnSF
RnPSF
RnSF
RnPSF
RnSF
RnPSF
RnSF
RnPSF
RnSF
A
RnPSF
RnSF
RnPSF
RnSF
RnPSF
RnSF
RnPSF
RnSF
RnPSF
RnSF
RnPSF
RnSF
APPX
881

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents