<Program name row>
The program name row for each column is displayed. (This row appears when the version of CPU Module Logging
Configuration Tool is "1.82L" or later and local devices or labels are specified. If the version is "1.76E" or earlier, or the version
is "1.82L" or later and only global devices are specified, this row does not appear.)
Item
Date column
Data collection interval column
Execution step No. column
Execution program number column
Execution program name column
Index column
Data column
Trigger occurrence information column
Ex.
The size of the program name row is determined by the following equation when data logging of 128 data points from D100 to
D227 is performed (The following sections in the "Output" window are set to be output: "Date", "Data sampling interval",
"Execution step No.", "Execution program name or execution program No.", and "Index". Also, devices from D200 to D227 are
specified as the local device of the program No.1 of "MAIN").
0(date column) + 0(data collection interval column) + 0(execution step number column) + 0(execution program number
column) + 0(execution program name column) + 0(index column) + (0  100 + 8  28)(data column) + 264(the number of tabs)
+ 4(CR + LF) = 492 bytes
<Device comment row>
The device comment row for each column is displayed.
Item
Date column
Data collection interval column
Execution step No. column
Execution program number column
Execution program name column
Index column
Data column
Trigger occurrence information column
*4 When "Output device comment" is selected in "Device comment output" of the output settings and double quotation marks (" ") and/or
commas (,) are included in a device comment, the size of data in use becomes larger than the size of the character string of the device
comments.
Ex.
The size of the device comment row is determined by the following equation when data logging of 128 data points from D100
to D227 is performed (The following sections in the "Output" window are set to be output: "Date" (the output format is YYYY/
MM/DD hh:mm:ss.sss), "Data sampling interval", "Execution step No.", "Execution program name or execution program No.",
"Index", and "Device comment output" (only for devices from D200 to D227)).
0(date column) + 0(data collection interval column) + 0(execution step number column) + 0(execution program number
column) + 0(execution program name column) + 0(index column) + (0  100 + 14  28)(data column) + 264(the number of
tabs) + 2(CR + LF) = 660 bytes
Description
No output (blank).
When the collected data is a local device or local label, the specified program name (no
extension) is displayed.
When the collected data is a global device or global label, this field is blank.
No output (blank).
Description
No output (blank).
When "Output device comments for data" is selected in the output setting, the comment with
the specified comment number is displayed.
When "Output each program device comment" is selected (when bit 9 of the added-data
information is turned on), the comment with the specified comment number in the device
comment file for each program is output only for the local device.
When the device comment file for each program or the comment of the corresponding
program does not exist, the comment of the device comment file is output.
When comments are not output, this field is blank.
No output (blank).
Appendix 13 How to Use CPU Module Logging Configuration Tool
Size
0 byte
0 to 120 bytes
0 byte
Size
A
0 byte
*4
0 to 2048 bytes
0 byte
APPX
953