Mitsubishi Electric MELSEC iQ-R-R00CPU User Manual page 174

Melsec iq-r series cpu module application user's manual
Table of Contents

Advertisement

Devices to be collected
The following table lists the devices that can be specified as the collected data.
Type
*2
Bit device
*3
Word device
Double-word device
*1 An index modified device and indirectly specified device cannot be specified.
*2 For bit devices, digit specification is allowed for K1 to K8 only.
*3 For word devices, bit specification is allowed.
*4 To specify the local device, use "Program name/#Device name". (Example: "MAIN/#M1")
*5 To specify these devices with CPU Module Logging Configuration Tool, use T (contact): TS, T (coil): TC, ST (contact): STS, ST (coil):
STC, C (contact): CS, C (coil): CC, LT (contact): LTS, LT (coil): LTC, LST (contact): LSTS, LST (coil): LSTC, LC (contact): LCS, and LC
(coil): LCC.
*6 The device can be collected by using the CPU module where the SFC function can be used. ( Page 1008 Added and Enhanced
Functions)
Labels to be collected
The following table lists the labels that can be specified to be collected.
Type
Global label
*3
Local label
*1 A label with a name of 256 characters or less can be specified. When the local label is specified (program block name/label name), the
"program block name/" part is counted as the number of characters.
*2 Only labels in the read project of the engineering tool can be specified.
*3 Specify the label with "Program block name/Label name". (Example: "ProgPou/label_w1")
*4 Digit-specified labels cannot be specified.
*5 Bit specification is allowed.
*6 For the label of timer type and counter type, specify the element name. (S: contact, C: coil, N: current value)
Global label example: "label_w1.S"
Local label example: "ProgPou/label_w1.S"
*7 Specify the array element. If the array element is not specified, it is handled as the start of the array ([0]). ( Page 969 Data)
*8 Specify the structure member. ( Page 969 Data)
When specifying a label, save the project of the engineering tool that contains the label in advance because
the project is imported into CPU Module Logging Configuration Tool.
11 DATA LOGGING FUNCTION
172
11.1 Data to Be Collected
*1
Device
*4
*4
X, DX, Y, DY, M
, L, F, SM, V
, B, SB, T (contact)
*4*5
*4*5
(coil)
, LT (contact)
, LT (coil)
*6
Jn\SB, Jn\B, BLn\S
*4
T (current value)
, ST (current value)
U3En\G, U3En\HG
*4
LT (current value)
, LST (current value)
Class
• VAR_GLOBAL
• VAR_GLOBAL_RETAIN
• VAR
• VAR_RETAIN
*4*5
*4*5
, T (coil)
, ST (contact)
*4*5
*4*5
*4*5
, LST (contact)
, LST (coil)
*4
*4
*4
, C (current value)
, D
, SD, W, SW, RD, R, ZR, Z, FD, Un\G, Jn\W, Jn\SW,
*4
*4
, LC (current value)
, LZ
*1*2
*4*5
*4*5
, ST (coil)
, C (contact)
*4*5
*4*5
, LC (contact)
, LC (coil)
, FX, FY, Jn\X, Jn\Y,
Data type
*7
■Primitive data type/array
*4
• Bit
*5
• Word (signed)
• Double word (signed)
*5
• Word (unsigned)
• Double word (unsigned)
• Single-precision real number
• Double-precision real number
• Time
• String
*6
• Timer type
*6
• Retentive timer type
*6
• Counter type
*6
• Long timer type
*6
• Long retentive timer type
*6
• Long counter type
*8
■Structure
*4*5
, C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents