Event
Event
Event
Detected event
code
type
category
20100
Operation
Info
Error clear
20200
Event history clear
20300
SD memory card
enabled
20301
SD memory card
forcibly disabled
20400
Firmware update
succeeded
(RnCPU)
20401
Firmware update
failed (RnCPU)
20420
Firmware update
succeeded
(RnENCPU)
20421
Firmware update
failed (RnENCPU)
20500
CPU module data
backup succeeded
20501
CPU module data
backup failed
20502
CPU module data
restoration
succeeded
20503
CPU module data
restoration failed
20510
CPU module data
backup setting
disabled
20600
iQ Sensor Solution
data backup
succeeded
20601
iQ Sensor Solution
data backup failed
20602
iQ Sensor Solution
data restoration
succeeded
20603
iQ Sensor Solution
data restoration
failed
20610
iQ Sensor Solution
data backup start/
cancel/end
20611
iQ Sensor Solution
data restoration
start/cancel/end
20620
Right-to-use
acquisition/release
Description
The error was cleared.
The event history was cleared.
The SD memory card was enabled.
The SD memory card forced disable
function was executed and the SD
memory card became ready to be
removed.
The firmware of the RnCPU was
successfully updated.
The firmware update of the RnCPU failed.
The firmware of the RnENCPU was
successfully updated.
The firmware update of the RnENCPU
failed.
Data in the CPU module were
successfully backed up.
Backup of data in the CPU module failed.
Data were successfully restored to the
CPU module.
Restoration of data to the CPU module
failed.
Backup function cannot be set
Data in the target device supporting iQ
Sensor Solution were successfully
backed up.
Backup of data in the target device
supporting iQ Sensor Solution failed.
Data were successfully restored to the
target device supporting iQ Sensor
Solution.
Restoration of data to the target device
supporting iQ Sensor Solution failed.
The data backup processing of the target
device supporting iQ Sensor Solution
started, canceled, or ended.
The data restoration processing of the
target device supporting iQ Sensor
Solution started, canceled, or ended.
The right to use the data backup/
restoration function of iQ Sensor Solution
was acquired or released.
Detailed information
Detailed
Detailed
information 1
information 2
Operation
Operation target
source
information
information
Firmware
update
information
(RnCPU)
Firmware
Firmware
update
update
information
information
(RnENCPU
(RnENCPU
(CPU part))
(network part))
CPU module
Target folder
data backup/
information of
restoration
the CPU
information
module data
backup/
restoration
function
CPU module
data backup
setting
information
Information on
Target device
the execution
information of
status of the
the data
data backup/
backup/
restoration
restoration
function of iQ
function of iQ
Sensor Solution
Sensor Solution
Data backup/
restoration
information of
iQ Sensor
Solution
Information on
the right to use
the data
backup/
restoration
function of iQ
Sensor Solution
Appendix 2 Event List
Detailed
information 3
A
APPX
795